True Power Online UPS- A Benchmark for Gen Next
As new and innovative technologies have become the backbone of today's businesses, maximum system availability is critical and downtime is more expensive than ever. Increasingly, businesses need a UPS that not only protects against blackouts, but also virtually eliminates more frequent and subtle power disturbances. Surges, sags, line noise and brownouts can disrupt proper operation of sensitive equipment. These disturbances may also create unnecessary production, service, and data recovery costs.
True Power UPS provides the highest level of protection against the widest spectrum of power problems.
- Double Conversation Technology
- Short circuit and Overload protection
- Generator Compatible
- 1phase in ~ 1 Phase out (up to 10 kva)
- phase in ~ 1 phase out (up to 40 kva)
- phase in ~ 3 Phase out (up to 100 kva)
- Wide Input Voltage range
EON Technical Specifications
Capacity |
1-5 5-7.5 10-50 above 50 |
Technology |
PWM IGBT Technology |
Dc Bus Voltage |
72/120/180360/432 v |
Input Voltage |
230+20% FOR SINGLE PHASE 415+20% for three phase |
Input Frequency |
50 Hz+10% |
Rectifier/Charger |
Float cum Boost charger (CV/CC Type) |
Battery Type |
SMF |
Back up Time |
Depend on Load & Battery Used |
Out put Voltage |
230 v+1% AC single phase 415+1% AC three phase |
Out put Frequency |
50 Hz+0.05 Hz (Crystal controlled) |
Out put Wave Form |
Pure Sine Wave |
Harmonic Distortions |
Less Than 3% |
Efficiency |
>93% for 360v DC & above
>90% for 180v DC
>85% for 48 vDC/72 vDc |
Power Factor |
0.8 lagging to Unity |
Over load |
110% for 10 minutes, 200% for 5 cycles, 300% for 1/2 cycles |
Crest Factor |
>3:1 |
Transient Recovery |
Within 3 Cycles |
Audible Noise |
Less than 55db at 1 meter upto 10 KVA
Less than 60db at 1 meter above 10 KVA |
Ambient Temperature |
Operating :0-50 degree C
Storage :0-60 degree C |
Relative Humidity |
95% Maximum (Non condensing) |
Indications |
Mains On, Battery Boost, Load On Batteries, Inverter On, Battery Low, Inverter Overload |
Protections |
Inverter: Over Load, Short Circuit
Battery: Overcharge, Over discharge, Short Circuit |
Cooling |
Inbuilt Instrumentation |
Self Testing & Diagnostic features |
An electronic circuit with digital logics continuously searches for the following faults and trips the system with audio-visual indication: Battery Over/Under Voltage output AC Over Voltage Output Overload/Short Circuit Phase fail for three phase models. |
Note: Specification & models subject to change due to continuous Technological improvements. |
|